How the Data Is Reduced

This page summarizes the reduction workflow used to produce cleaned Chandra cluster data products for the archive.

Reduction workflow

  1. Start from publicly available Level 1 event files from the Chandra archive for each ObsID.
  2. Reprocess observations with standard CIAO/CALDB calibration updates to generate clean Level 2 event files.
  3. Remove background flares: detect point sources on the chip least affected by the target, drop them, and clip the high-background periods from its light curve.
  4. Subtract the scaled ACIS blank-sky background and merge all ObsIDs of an object into exposure-corrected images in the broad (0.5–7 keV), soft and hard bands. The images keep all point sources.
  5. Check that every ObsID of an object is in its merged images in every band before publication.
Data release (DR1) DOI: 10.5281/zenodo.24351915

If you use these results in your work, please cite: 10.5281/zenodo.18728228, and for the catalog tables also the data release, 10.5281/zenodo.24351915. A paper describing the LEMUR catalog is coming soon; once it is published, please cite it as well.